MIL-DTL-19834C
TABLE III. First article inspection.
Examination
Number
Requirement
Method
or test
of samples
Paragraph
paragraph
4.6.2
3.1, 3.3.1,
All
Examination - - - - - - - - -
3.3.2, 3.4.1,
3.4.2, 3.6, 3.7,
and 3.8
4.6.7
3.5.6
2
Accelerated light and weather resistance - - - - - - - - - - - -
4.6.8
3.5.7
2
Salt spray resistance - - - - - - - - - - - - - - - - - - - - - - - - -
4.6.3
3.5.2
2
Abrasion resistance - - - - - - - - - - - - - - - - - - - - - - - - - -
4.6.4
3.5.3
10
Edge adhesion - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
4.6.5
3.5.4
10
Cyclic exposure - - - - - - - - - - - - - - - - - - - - - - - - - - - -
4.6.6
3.5.5
2
Accelerated oxygen aging - - - - - - - - - - - - - - - - - - - - -
4.6.9
3.5.8
10
Water resistance - - - - - - - - - - - - - - - - - - - - - - - - - - - -
4.6.10
3.5.9
20
Fuel resistance - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
4.6.11
3.5.10
10
Cleaning resistance - - - - - - - - - - - - - - - - - - - - - - - - - -
4.6.12
3.5.11
10
Temperature range - - - - - - - - - - - - - - - - - - - - - - - - - -
4.4.3 Failures. One or more failures shall constitute failure of this test.
4.4 Conformance inspection.
4.4.1 Sampling. Unless otherwise specified, sampling from each lot for examination and inspection shall
be selected in accordance with table IV and shall be based on a zero acceptance sampling plan.
TABLE IV. Sampling plan for identification plates.
Lot size
Sampling size
100%
1-13
13
14-150
20
151-280
29
281-500
34
501-1,200
42
1,201-3,200
50
3,201-10,000
60
10,001-35,000
74
35,001-150,000
90
150,001-500,000
102
500,001- and over
4.4.1.1 Inspection lot. An inspection lot shall consist of all identification plates of the same size produced
under essentially the same conditions and offered for inspection at one time.
4.4.2 Examination. The samples selected in accordance with 4.4.1 shall be examined for compliance with
the examination requirements specified in table III of this specification.
4.4.3 Inspection. Conformance inspection shall consist of all the inspection specified in 4.6. If one or
more sample units fail to pass the inspection, the sample shall be considered to have failed.